Draft — awaiting physician review. This page explains power arithmetic using manufacturer specifications. It is not medical advice. Talk to your doctor or your equipment supplier before relying on any backup plan for a medical device.
Find your device’s power rating in its manual, then divide a battery’s usable energy by it. A ResMed AirSense 11 CPAP with humidifier is rated at up to 56.1 W (ResMed AirSense 11 User Guide (English, PDF hosted by NIH StrokeNet), Technical specifications); a Philips EverFlo home oxygen concentrator about 350 W (Philips EverFlo home oxygen system, specifications page (Philips Australia)). At those maximum ratings a 1,000 Wh station would run the CPAP about 15 h and the concentrator about 2.4 h.
Real stations at the maximum ratings
| Station | Capacity | CPAP (56.1 W) | Concentrator (350 W) |
|---|---|---|---|
| Westinghouse iGen1000s | 1,008 Wh | 15 h | 2.4 h |
| EcoFlow DELTA 3 Max Plus | 2,048 Wh | 31 h | 5 h |
| Goal Zero Yeti 6000X | 6,071 Wh | 92 h | 14.7 h |
Rated maximums overstate typical use; actual draw depends on settings, humidifier use and model. Your manual or supplier can give the figure for your device. The 1-in-10 outage is 4.6 h in the typical county and 7.5 h in the hardest-hit tenth.
Questions to ask your equipment supplier
- What is my device’s actual power draw at my settings?
- Does the maker sell a battery or DC power cord for it, and is the device approved for use on a power station or generator?
- Do I have a backup supply (for oxygen users, cylinders that need no power) and how long does it last?
Tell your utility
Many utilities run medical-baseline or priority-notification programmes for customers who rely on powered medical equipment. Your county page links your utility where we have it. Registration does not guarantee faster restoration.
Runtime calculator Backup Matcher Look up your county
Power stations are indoor-safe; fuel generators never are. Never run a generator indoors or in a garage — carbon monoxide kills.