A sump pump runs only when water comes in, so what matters is pump-running hours, not clock hours. A ⅓ hp pump draws about 800 W running (1,300 W to start) and a ½ hp about 1,050 W (2,200 W to start) per Eugene Water & Electric Board (EWEB), Generator Sizing Considerations (PDF). A 2,000 Wh battery gives a ½ hp pump about 1.6 hours of running — which can stretch across a long outage in light rain, or vanish in one storm night.
Your own duty cycle
Time your pump in a heavy rain: if it runs 15 seconds every 2 minutes, it is running one-eighth of the time, so each pump-running hour covers about 8 clock hours. We don’t know your basement’s inflow; nobody can estimate it for you without timing it.
Two kinds of backup
- A dedicated backup pump (a second, usually 12 V DC, pump on its own battery) sits beside the main pump and takes over if it fails or power is lost — it also covers a jammed float or a dead main pump.
- Powering your existing pump from a power station or generator, which must cover the starting surge.
Power stations that clear a ½ hp start
- Westinghouse iGen1000s: 1,008 Wh → about 0.8 pump-running hours
- Bluetti Elite 100 V2: 1,024 Wh → about 0.8 pump-running hours
- EcoFlow DELTA 3: 1,024 Wh → about 0.8 pump-running hours
- EcoFlow DELTA 3 Classic: 1,024 Wh → about 0.8 pump-running hours
The 1-in-10 outage is 4.6 h in the typical county and 7.5 h in the hardest-hit tenth; your county page shows yours.
Keep batteries off the floor where water collects and follow the maker’s charging and ventilation instructions; flooded lead-acid batteries vent hydrogen while charging. Any fuel generator runs outdoors only, never in a basement or garage.
Runtime calculator Backup Matcher Generator size calculator Look up your county