What size generator do I need? A worked example with sourced wattages

Add the running watts of everything you want on at once, add the largest extra starting surge of any motor (fridge, sump pump, well pump, AC), and choose a generator whose rated watts are at least the running total ÷ 0.8 and whose starting watts cover the surge.

Worked example (sourced wattages)

  • Refrigerator 700 W running (+2200 W to start)
  • ½ hp sump pump 1050 W (+2200 W to start)
  • Gas furnace blower 700 W
  • 10 LED bulbs × 15 W

Running total 2,600 W; with the largest motor starting 4,800 W; recommended rating ≈ 3300 W. Wattages come from utility generator-sizing guides; your appliance labels win.

Then plan fuel for your outages

Generator size decides what can run; fuel decides for how long. Check your county’s major-storm outage length and the generator’s published run time before deciding between gasoline, propane or a natural-gas standby unit.

Use the generator size calculator

Generators run outdoors only, away from windows, doors and vents. Connect to house circuits only through a transfer switch or interlock installed by a licensed electrician.