Add the running watts of everything you want on at once, add the largest extra starting surge of any motor (fridge, sump pump, well pump, AC), and choose a generator whose rated watts are at least the running total ÷ 0.8 and whose starting watts cover the surge.
Worked example (sourced wattages)
- Refrigerator 700 W running (+2200 W to start)
- ½ hp sump pump 1050 W (+2200 W to start)
- Gas furnace blower 700 W
- 10 LED bulbs × 15 W
Running total 2,600 W; with the largest motor starting 4,800 W; recommended rating ≈ 3300 W. Wattages come from utility generator-sizing guides; your appliance labels win.
Then plan fuel for your outages
Generator size decides what can run; fuel decides for how long. Check your county’s major-storm outage length and the generator’s published run time before deciding between gasoline, propane or a natural-gas standby unit.
Use the generator size calculator
Generators run outdoors only, away from windows, doors and vents. Connect to house circuits only through a transfer switch or interlock installed by a licensed electrician.